icon

Intraoperative Monitoring (IONM)

Cascade PRO® IONM System

Pod‑Based 16–32 Channel Neuromonitoring for Every OR


Cascade PRO® delivers flexible, high‑fidelity intra‑operative neuro­monitoring (IONM) in a portable package that scales effortlessly from routine spine cases to complex cranial procedures. Its pod‑based architecture, choice of one or two 16‑channel amplifiers, and powerful Cascade Surgical Studio™ software give technologists the freedom to configure exactly what each surgery demands—on a roll‑in cart, a slim tower, or a grab‑and‑go laptop station.

Key Features
  • Scalable Channel Capacity: Start with one 16‑channel amplifier for routine EMG, SSEP, and MEP cases. Add a second 16‑channel pod to reach 32 simultaneous channels for multi‑modality cranial, peripheral‑nerve, or multi‑level spine monitoring. Input‑extender pods keep leads short and clean at the sterile field while the base stays safe on the cart.
  • All‑Modality PRO Base Unit: Built‑in auditory and visual EP stimulators plus electrosurgery and noise detectors—no external boxes. Universal patient‑event input records surgeon requests or anaesthesia events directly into the trace.
  • Peripheral & Trigger Stimulators: Select constant‑current or constant‑voltage hand probes, train‑of‑four stimulators, and trans‑cranial stimulators to tailor every case.
  • Portable or Cart‑Based Workflow: Lightweight amplifier pods clip to the drape or table to minimise cable drag. Choose compact carry‑case portability, the purpose‑built C2 cart, or integrate into an existing OR tower.
  • Trusted Cascade Surgical Studio™ Software: Intuitive multi‑modality workspace with automatic thresholding, real‑time trending, and templated reports. Networked Sentinel™ monitoring lets off‑site specialists review live traces and video when needed.
Why Choose Cascade PRO®?
  • : Configure for any surgery—swap pods and stimulators to build 16‑ or 32‑channel set‑ups in minutes.
  • : Keep the field tidy—patient‑side pods shorten lead runs, reduce artefact, and speed turnover.
  • : All stimulators on board—auditory, visual, ESU‑detect, and noise‑detect live in the PRO base, so there is less to wheel in.
  • : Move as your programme grows—from outpatient spine to multi‑modality cranial, Cascade PRO adapts without a hardware overhaul.
  • : Seamless software ecosystem—Cascade Surgical Studio ties acquisition, remote review, reporting, and archive into one workflow trusted in ORs worldwide.

Cascade PRO® gives neuro­monitoring teams the versatility, portability, and clinical depth required to help protect neural function across the full spectrum of surgical care—day after day, case after case.

Have a question? We would love to hear from you.


Contact Us